REEMAN Industrial Plant Equipment

Flowmeter 8732EMR2A5K1AXM4C1B6Q4V2RT05HR7 Emerson

Flowmeter 8732EMR2A5K1AXM4C1B6Q4V2RT05HR7 Emerson
Flowmeter 8732EMR2A5K1AXM4C1B6Q4V2RT05HR7 Emerson

Flowmeter 8732EMR2A5K1AXM4C1B6Q4V2RT05HR7 Emerson


  • رقم القطعة: 8732EMR2A5K1AXM4C1B6Q4V2RT05HR7
  • الفئة: Flowmeter
  • الشركة المصنعة: Emerson
  • بلد المنشأ: Germany Country Germany
  • تاريخ الإصدار: 2025-09-20 10:09:39
  • فترة الانتظار: 3 to 4 working weeks
  • الحالة: New
  • رابط ورقة البيانات:
  • SKU: 36313491
  • التوفر: On Request

Rosemount 8700M Magnetic Flowmeter
8732EM = Base model: Magnetic Flowmeter Transmitter - Field Mount
R=Mounting style: Remote Field Mount
2=Power supply: DC Power Supply (12 - 42 VDC)
A=Outputs: 4-20 mA Output with Digital HART Protocol & Scalable Pulse Output
5=Conduit entry: M20–1.5, Additional Entry — Integral mount qty (3), remote mount qty (5)
K1=Hazardous area certifications: ATEX Flameproof with Increased Safety, ATEX Dust
AX=Discrete input/discrete output: Two Discrete Channels (DI/DO 1, DO 2)
M4=Display: Local Operator Interface
C1=Miscellaneous: Custom Configuration
B6= 316 SST Mounting Bracket with 4-bolt Kit for 2-in. Pipe Mount
Q4=Quality certificate: Calibration Data, per ISO 10474 3.1 / EN 10204 3.1
V2=Paint: Offshore/Near Shore Marine Paint (3 layer epoxy)
RT05=Remote cable kit: Standard Temperature Component Cables – -4 °F to 167 °F (-20 °C to 75 °C) for 50 ft
HR7=Revision configuration: HART Revision 7
التوصيل: UPS، FedEx و DHL
توصيل دولي متاح
شحن في نفس اليوم للمتوفر في الموقع
يمكن التفاوض على تفاصيل الشحن
سياسة الشحن المجمع: نقوم بدمج الشحنات لتقليل التكاليف للعملاء الذين يشترون عدة عناصر.
بعد إتمام العملاء لعمليات الشراء المتعددة، يجب عليهم طلب فاتورة.
سنقوم بتغليف ووزن الشراء بالكامل وتقديم فاتورة تشمل الشحن والتعبئة.
الضمان: جميع منتجاتنا مغطاة بضمان ريمان
سنقوم بتسجيل فيديو اختباري قبل الشحن
✓ ضمان 30 يومًا - قطع مجددة
الإرجاع: سياسة إرجاع بدون تعقيدات.
عروض أسعار سريعة: احصل على السعر والتوفر اليوم!
الدفع:
You have already visited today.Today's Visitors: 943
Yesterday's Visitors: 984
Total Visits: 564643
Most Visitors on 2026-05-18: 2949
Pages Visited in the Last 24 Hours:
- /product/Indicator-703041-181-140-25-000-dTRON-316-Jumo
- /product/Temperature-3144P-D6A2I1M5T1Q4U1QTXA-Rosemount
- /product/PH-ORP-Conductivity-DO-Analyzer-3-2726-10-GF
- /
- /
- /categories/Level
- /categories/DAQ
- /categories/Flowmeter
- /categories/Valves
- /categories/Temperature
- /categories/Gas-Detection
- /categories/Pressure
- /categories/PH-ORP-Conductivity-DO-Analyzer
- /product/Level-FEW54-Endress-Hauser
- /product/Level-FTS-20-Endress-Hauser
- /product/Indicator-HXDSBOXAI-485-JIT
- /manufacturer-popular/Turck
- /manufacturer-popular/Advantech
- /manufacturer-popular/CTC
- /manufacturer-popular/samson
- /manufacturer-popular/Rosemount
- /manufacturer-popular/IFM
- /product/PH-ORP-Conductivity-DO-Analyzer-3-9900-1P-GF
- /manufacturer-popular/ABB
- /product/Level-FMR51-Flang-Endress-Hauser
- /product/Pressure-700G05-FLUKE
- /manufacturer-popular/Pepperl-Fuchs
- /manufacturer-popular/JIT
- /manufacturer-popular/Moxa
- /manufacturer-popular/OMRON
- /manufacturer-popular/PHOENIX-CONTACTS
- /manufacturer-popular/B-K
- /manufacturer-popular/Emerson
- /manufacturer-popular/Fisher
- /manufacturer-popular/Vega
- /manufacturer-popular/WIKA
- /product/Level-DTI200-A14A1A-Endress-Hauser
- /manufacturer-popular/Endress-Hauser
- /manufacturer-popular/Schneider
- /manufacturer-popular/Bently-Nevada
- /product/Level-T32-1S-0IS-LVL-KSR-Kuebler
- /manufacturer-popular/Siemens
- /manufacturer-popular/National-instrument
- /manufacturer-popular/Yokogawa
- /manufacturer-popular/KSR-Kuebler
- /product/Pressure-EJA110A-EHS4B-22DB-Yokogawa
- /manufacturer-popular/Allen-Bradley
- /manufacturer-popular/KROHNE
- /product/Proximity-31000-16-10-00-159-00-02-Bently-Nevada
- /product/Level-FTS-20-Endress-Hauser
- /product/Level-RTG-3960-Emerson
- /product/Indicator-Head-indicator-pressure-JIT
- /product/Level-FMU90-R21CA232AA3A-Endress-Hauser
- /product/Proximity-IG5497-IFM
- /product/Portable-ZX21-Resistor-Junction-JIT
- /product/Proximity-NG5010-IFM
- /product/Temperature-5081-P-HT-Rosemount
- /product/Accessory-0306RT22BA11-Rosemount
- /product/Valves-Y53-Other
- /product/Level-2051L2AB4GD21AAF1C1-Rosemount
- /product/Temperature-248RANA-Rosemount
- /product/Flowmeter-DK800-R-RA-KROHNE
- /product/Proximity-IN0108-IFM
- /product/DAQ-DAM-3058F-JIT
- /product/Level-FEL56-Endress-Hauser
- /product/Level-FEL58-Endress-Hauser
- /product/Level-FMR53-Endress-Hauser
- /product/Level-FEL85-Endress-Hauser
- /product/Level-FHB20-Endress-Hauser
- /product/Level-FMP40-7KK2AEJB2BJA-Endress-Hauser
- /product/Level-FMP40-ABB2AWJB213A-Endress-Hauser
- /product/Level-FTM20-AM43A-Endress-Hauser
- /product/Pressure-2051TG-Rosemount
- /product/Flowmeter-8600DF040SK1N2P1RM-Rosemount
- /product/Level-ftm51-aahcs4a13aa-Endress-Hauser
- /product/Pressure-1301F-Fisher
- /product/Lvdt-AC192-1D-CTC
- /product/DAQ-PD3060-PT100-JIT
- /product/Level-FDU96-RG1A-Endress-Hauser
- /product/Level-FDU92-RG6A-Endress-Hauser
- /product/Vibration-AC192-1A-CTC
- /product/Temperature-644HANAM5-Emerson
- /product/Pressure-PMC731-R11S1E21M1-Endress-Hauser
- /product/Indicator-C72-k301-PE-JIT
- /product/Level-FTL62-AAA2ACATT2CTEBE2T-Endress-Hauser
- /product/Flowmeter-CMFS100M329N3E6E2ZZ-Micro-Motion
- /product/Temperature-444RL2U1D2C6-Rosemount
- /product/Level-fmr51-Endress-Hauser
- /product/Temperature-TT4C-JIT
- /product/Temperature-TMT182-ACKBA-Endress-Hauser
- /product/Level-FTL51B-AAA2ABAAA2CCI1VCC-Endress-Hauser
- /product/Temperature-3044CA1B4M5-Rosemount
- /product/Level-FTM51-AGJ2M4D13AF-Other
- /product/Accessory-52028122-Endress-Hauser
- /product/Level-FMU43-APH2A2-Endress-Hauser
- /product/Pressure-PMD75-ABA7FJ1DAAA-Endress-Hauser
- /product/Pressure-PMD75-HBA7B21DAAA-Endress-Hauser
- /product/Pressure-PMD75-ABA7C21DAAA-Endress-Hauser
- /product/Level-FMP40-1AA2ADJB21CY-Endress-Hauser
- /product/DAQ-SCB-68-National-instrument
- /product/Level-VEGAMET-861-Vega
- /product/Pressure-BWX-WIKA
- /product/Accessory-52028092-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-Endress-Hauser
- /product/DAQ-NI-9237-National-instrument
- /product/Level-FMB50-AA21RA-Endress-Hauser
- /product/Pressure-PMD75-ABA7F21DAAA-Endress-Hauser
- /product/Level-FMU40-ARB2A2-Endress-Hauser
- /product/Level-FTL33-AA4U3ABWSJ-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-COS41-4F-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CLM223-CD0110-Endress-Hauser
- /product/Temperature-TR66-AEABC2X22KA0-Endress-Hauser
- /product/Flowmeter-AD25AAAAABAA1-Endress-Hauser
- /product/Pressure-2290PG1-Rosemount
- /product/Level-FMP54-BAACCAAED2YYY-EFMB-Endress-Hauser
- /product/Flowmeter-93WA1-AB2C10ACABAA-Endress-Hauser
- /product/Pressure-PMD75-ABC7B21BAAA-Endress-Hauser
- /product/DAQ-9203-National-instrument
- /product/Proximity-LR12-D150N1D-JIT
- /product/Level-FTL51-ATE2CB4E5A-Endress-Hauser
- /product/Flowmeter-UD0A1AA0AAAA-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-LEVEL-Endress-Hauser
- /product/Level-FMU40-ARB1A2-Endress-Hauser
- /product/Pressure-PMD75-ABA7H21DAAA-Endress-Hauser
- /product/Vibration-LP202-4R1-1E-CTC
- /product/Pressure-PMD75-ABC7D21BAAA-Endress-Hauser
- /product/Level-FMR245-7GCQKAA2-Endress-Hauser
- /product/Level-FMR50-AAAAAABMGGF-Endress-Hauser
- /product/Flowmeter-55S1H-UR0B2AC4BAAA-Endress-Hauser
- /product/Level-FTL51-GAF2BB8G6R-Endress-Hauser
- /product/Level-FTL31-AA4U3BAWSJ-Endress-Hauser
- /product/Temperature-3144PD1A1NAM5XA-Rosemount
- /product/Proximity-IPS-308-OP-18-JIT
- /product/Pressure-PMD75-ABA7C21BASA-Endress-Hauser
- /product/Level-FMR51-FDACCDBBA5ARJ-AAJALA75-Endress-Hauser
- /product/Level-FMP40-5PP2CRJB21AA-Endress-Hauser
- /product/Level-FMR52-8L68-0-Endress-Hauser
- /product/Indicator-HZN-450755P0224-ABB
- /product/Level-FMP51-AACCCDLBB3RDJ-EBZ1-Endress-Hauser
- /product/Pressure-PMC71-1BA2FBRDAAA-Endress-Hauser
- /product/Pressure-3051TG3A2B-Rosemount
- /product/Level-FMU40-1RB2A4-Endress-Hauser
- /product/Gas-BH-60-H2S-JIT
- /product/Pressure-PMD75-ACA7C212AAA-Endress-Hauser
- /product/Pressure-S-20-WIKA
- /product/Proximity-330130-Bently-Nevada
- /product/Flowmeter-5P2B80-4P14-101-Endress-Hauser
- /product/Level-FTM20-4G42A-Endress-Hauser
- /product/Flowmeter-53P40-ASGB4DA0AAAA-Endress-Hauser
- /product/Level-FTL50-GGF2AA7G5A-Endress-Hauser
- /product/Power-Electric-SH201-C20-ABB
- /product/Temperature-4253A01R4AA00-Other
- /product/PLC-HMI-FX2N-40M-JIT
- /product/Level-FMR532-1WC8JAC2GA-Endress-Hauser
- /product/Level-FDU93-TN1A-Endress-Hauser
- /product/Pressure-S-10-WIKA
- /product/Level-FMP51-AAACCALAA4RGJ-AA-Endress-Hauser
- /product/Level-FMP40-7KK3AFJB21GB-Endress-Hauser
- /product/Accessory-71319979-Endress-Hauser
- /product/Flowmeter-5P2B50-5PL3-125-Endress-Hauser
- /product/Flowmeter-53P4H-EL2B2AA0AAAA-Endress-Hauser
- /product/Pressure-1151DP5S22C2M7Q4-PRESSURE-Rosemount
- /product/Pressure-PMD75-5BA7D21BAAA-Endress-Hauser
- /product/Level-FTL81-BBSAAAA1ACJWDJ-Endress-Hauser
- /product/Proximity-330103-Bently-Nevada
- /product/Pressure-FMB70-ABA1HA2CFCAA-Endress-Hauser
- /product/DAQ-cDAQ-9188-National-instrument
- /product/Pressure-PMD75-ABA7F21BAAA-Endress-Hauser
- /product/Pressure-PMD75-ABA7L12FAQK-NVN8Z1-Endress-Hauser
- /product/Accessory-2-3-9300-108-Rosemount
- /product/Pressure-700G05-FLUKE
- /product/Accessory-XPD0037-AAA100-Endress-Hauser
- /product/Accessory-TID10-E1-Endress-Hauser
- /product/Temperature-TMT162-F2121KBKA-Endress-Hauser
- /product/Pressure-PMD75-AAA7L11BAAA-Endress-Hauser
- /product/Level-FTL51-RAF2CB4E5A-Endress-Hauser
- /product/Level-BGU-E-KSR-KUEBLER
- /product/PH-ORP-Conductivity-DO-Analyzer-CLM431-H3B2IA-Endress-Hauser
- /product/Vibration-VC-1100-C11-B-K
- /product/Level-FMP40-1KK2AMJK21AN-Endress-Hauser
- /product/Level-FTL62-BBA7ABANN2CNEAE2JEH-Endress-Hauser
- /product/Temperature-644-1050-0001-AF-Rosemount
- /product/Level-FMM20-B14B1AD1G1-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-NH-KpH-JIT
- /product/Flowmeter-53P80-ECHB1AA0ABAA-Endress-Hauser
- /product/Pressure-FMD76-ABA7H2KBAA-Endress-Hauser
- /product/Accessory-K9803HC-Yokogawa
- /product/Proximity-330104-Bently-Nevada
- /product/Level-FTM51-1YY2L8A32AY-Endress-Hauser
- /product/Power-Electric-MK3P-I-OMRON
- /product/Pressure-3051CD2A22A1AS2B4-Rosemount
- /product/Level-FMU44-AVB2A22A-Endress-Hauser
- /product/Level-FTL51-EAE2BB4F7A-Endress-Hauser
- /product/Flowmeter-5H3B15-AAIBAEAFAAFDAS0AA2-LPLT-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-400VP-11-Rosemount
- /product/Temperature-TPR100-BXX2CCAA0-Endress-Hauser
- /product/Flowmeter-40E15-AFTSAABAA5AA-Endress-Hauser
- /product/Pressure-2051CG5A02A1AH2B1M5DF-Rosemount
- /product/Valves-TZIDC-V18345-ABB
- /product/Level-FTL20-042C-Endress-Hauser
- /product/Vibration-TK-83-Bently-Nevada
- /product/Level-FTM51-AB39M4A12AA-Endress-Hauser
- /product/Pressure-PMP46-RA13MBA1YYD-Endress-Hauser
- /product/Pressure-PMD75-78X49-142-Endress-Hauser
- /product/Level-FTM51-AGG2L2A32AA-LEVEL-Endress-Hauser
- /product/Level-FMU95-J11CAB31A-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUS31-A2E-Endress-Hauser
- /product/Pressure-3051CD1A02A1AM5B7DFK8H2L4T104-Rosemount
- /product/Pressure-3051CD4AC2A1AH2M5B1C6-Rosemount
- /product/Pressure-PMD75-570D3-264-Endress-Hauser
- /product/Proximity-BI20-G47-AZ3X-Turck
- /product/Pressure-1151GP6S22R1M7B3DFQ4-Rosemount
- /product/Accessory-K9800TA-Yokogawa
- /product/Temperature-TMT142-O1111JCKA1-Endress-Hauser
- /product/Accessory-6FX8002-5CS01-1AF0-Siemens
- /product/Pressure-PMD75-ANA7B21BAAA-Endress-Hauser
- /product/Temperature-3144PD2A1E5B4M5Q4-Temperature-Rosemount
- /product/Level-FMP55-BCACCBCAAGKAEJDLAOEZ1-Endress-Hauser
- /product/Pressure-PMP46-RE13MBA1YYD-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUS31-W2A-Endress-Hauser
- /product/Flowmeter-8F3B1H-BDECACGFABSDAASCA1-Endress-Hauser
- /product/Proximity-IB0016-IBE2020-FB0A-IFM
- /product/Level-FTM50-AGK2K4A32AA-Endress-Hauser
- /product/Temperature-TMT182-H31BA-Endress-Hauser
- /product/Temperature-248HANAN0NSQ4-Rosemount
- /product/Flowmeter-FMR57-AAACADBDA6RGJ2-AAOP-Endress-Hauser
- /product/Temperature-644HAK5M5J6Q4XA-Rosemount
- /product/Pressure-PMD75-HBA7F81DCAA-Z1-Endress-Hauser
- /product/Pressure-PMC71-ABA1C2GP1AA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2G-Endress-Hauser
- /product/Level-FTL50-AGN2AA2G5A-Endress-Hauser
- /product/Pressure-PMC71-ACA2FBGABAA-Endress-Hauser
- /product/Valves-YVP110-Yokogawa
- /product/Flowmeter-50P1F-AR0A1BA0B4AW-Endress-Hauser
- /product/Pressure-3051CD4A02A1BS5E5M5-Rosemount
- /product/Level-FTL51-KAE2BB4G5A-Endress-Hauser
- /product/Level-FMR51-AAACCABDA5AHJ-Endress-Hauser
- /product/Other-Manifold-5-way-Rosemount
- /product/Level-FMB51-AA22IA1FGD80GGJB2U-ABHC-Endress-Hauser
- /product/Level-FTM51-AGK2M2A32AA-Endress-Hauser
- /product/Level-FTL50-GAF2AA8G5C-Endress-Hauser
- /product/Level-FTL50-DGQ2AA4G4A-Endress-Hauser
- /product/Flowmeter-80F1F-CABSBACAABAA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM253-PR1616-Endress-Hauser
- /product/Level-FTL50-AGM2AA5E5A-Endress-Hauser
- /product/Temperature-TMT82-BAA2AB1A1AAA1-LA-Endress-Hauser
- /product/Flowmeter-5H3B04-BSIBAAAFAAAD5S1BA1-Endress-Hauser
- /product/Level-FTM20-4G42A-FEM24-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CLS50-G1B2-Endress-Hauser
- /product/Flowmeter-55S1H-UHJB1A34ADAB-Endress-Hauser
- /product/Level-FTM51-AGGAL2A34AA-Endress-Hauser
- /product/Pressure-3051L4AA0FD21AAM5C6-Rosemount
- /product/Pressure-PMP71-ABC1WC1RDAEA-Endress-Hauser
- /product/Flowmeter-65I-20AA0AD1RABACA-Endress-Hauser
- /product/Accessory-K9803WK-Yokogawa
- /product/Pressure-FMB52-BA22IA1FGA15CHJB2U-Endress-Hauser
- /product/Pressure-SDP6B45-A-250-Other
- /product/DAQ-USB-6009-OEM-National-instrument
- /product/Level-FMR240-43V1AEJAC4A-Endress-Hauser
- /product/Temperature-TMT182-A1KBA-Endress-Hauser
- /product/Level-FTL51C-ABGKBKDG4AA-Endress-Hauser
- /product/Level-VEGADIS-61-DIS61-CXAMD-Vega
- /product/Pressure-3051L4AADFD21AAC6M5-Rosemount
- /product/Flowmeter-GFC-300-KROHNE
- /product/Level-VEGASWING-61-DUABVXURX-Vega
- /product/Pressure-PMD75-1BJ7HE1DABA-Z1-Endress-Hauser
- /product/Level-PS62-UXCNE2FKNXX-Vega
- /product/Pressure-PMP71-ABC1U21RHAAA-Endress-Hauser
- /product/Gas-Detection-SC311S-100-ASSY-Emerson
- /product/Level-FMR231-AEGGJAA2AA-Endress-Hauser
- /product/Flowmeter-8750WDMR1A1FTSE015SA1M4Q4-Rosemount
- /product/Level-FTL50-YGQ2AA4G7A-Endress-Hauser
- /product/Level-FMP41C-SDTCKB21A4A-Endress-Hauser
- /product/Level-FTL51-FGR2BB7Y9A-Endress-Hauser
- /product/Pressure-3051L3AA0FD21AAM5C6-Rosemount
- /product/Pressure-PMP71-ABC1S21RAAAA-Endress-Hauser
- /product/Flowmeter-90WA1-AA2A10ACA4AA-Endress-Hauser
- /product/Level-FMU44-ATB2A23A-Endress-Hauser
- /product/Level-FTM50-AGG2A4D32AA-Endress-Hauser
- /product/Temperature-TMT182-1AAAA-Endress-Hauser
- /product/DAQ-PXI-6509-National-instrument
- /product/Flowmeter-FMU30-AAHEAAGGF-Endress-Hauser
- /product/Flowmeter-50P1F-BF5BRAC2AAAW-Endress-Hauser
- /product/Flowmeter-CMF050M-314NQFZEZZZHTMC-Emerson
- /product/Accessory-K9400FA-Yokogawa
- /product/Temperature-644HAE1J6M5Q4XA-Rosemount
- /product/Level-FMU30-AAHEABGHF-Endress-Hauser
- /product/Pressure-FMB70-AAA1H12CGCAA-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G4AA-Endress-Hauser
- /product/Pressure-PMD75-AAA7D21CAAU-Endress-Hauser
- /product/Level-FTL50-AGR2AA4G6A-Endress-Hauser
- /product/Pressure-2051L3AADFD21AAM5C6-Rosemount
- /product/Temperature-TR66-CCEEC2XCMDA0-Endress-Hauser
- /product/Accessory-K9802NA-Yokogawa
- /product/Flowmeter-8800CW060SD1N1D1Q4-Rosemount
- /product/Level-FMM50-A1A2A1AB11B1-Endress-Hauser
- /product/Pressure-PMC71-ABA1C2B4AAA-Endress-Hauser
- /product/Lvdt-VS-0169-B-K
- /product/Temperature-TR88-BB3B1D2MC0F0-Endress-Hauser
- /product/Flowmeter-8732EMR2A5K1AXM4C1B6Q4V2RT05HR7-Emerson
- /product/Level-FMR240-15K1YY9AA2D-Endress-Hauser
- /product/Power-Electric-3311DS1L1B2F2G7G8K5-Rosemount
REEMAN Industrial Plant Equipment REEMAN Industrial Plant Equipment L.L.C +971-509129535 +971-509129535 info@reemanindustrial.com