REEMAN Industrial Plant Equipment

Level 9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ Rosemount

Level 9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ Rosemount
Level 9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ Rosemount

Level 9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ Rosemount


  • رقم القطعة: 9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ
  • الفئة: Level
  • الشركة المصنعة: Rosemount
  • بلد المنشأ: Germany Country Germany
  • تاريخ الإصدار: 2025-11-30 11:11:01
  • فترة الانتظار: 3 to 4 working weeks
  • الحالة: New
  • رابط ورقة البيانات:
  • SKU: 67013491
  • التوفر: On Request

9930 Rosemount 9930 Magnetic Level Indicator
0 =Measurement type: Liquid level (gas/liquid interface)
68=Float selection: Float material=316 Stainless steel , Minimum SG=0.68 , Float max. operating pressure in psig (bar) at 100 °F (37.8 °C)=154 (10.6)
Chamber size and schedule=2 ½-in. S40 ,“A” Dimension in inches (mm)=12.0-in. (305 mm)
C=?
AB=Mounting style: ANSI/ASME B16.5 Class 300
1=Access flange type: Raised Face (RF) Weld Neck
M=Indicator scale unit of measure : Metric, millimeters
00813=Mounting dimension (center-to-center for style B, C, D, L, and top-tobottom for style A)
S=Chamber material: 316/316L Stainless steel (standard)
E=Side process connection design : Extrusion (limited to chamber size S10 or S40 with 1½-in. or 2-in. NPS process connection size)
2=Process connection size (NPS) : 2-in
AB=Process connection rating and type : ANSI/ASME B16.5 Class 300 , TYPE: 1, 2, 3, 4, Y
1=Process connection type and rating : RF Weld Neck , rating: AA, AB, AC, AD, AE, AF
4=Process connection schedule : S40
S=Process connection material : 316/316L Stainless steel (standard)
F= Top of the chamber: Flat cap
9=Top vent size: ¾-in.
C=Top vent type : SW tap only
8=Top vent schedule or rating: S80
B=Bottom of the chamber : Blind flange
9=Bottom drain size: ¾-in.
C=Bottom drain type: SW tap only
8=Bottom drain schedule or rating: S80
F=Indicator: Flag
A=Scale units: Metric (5 mm increments)
0=Indicator enclosure material : Anodized aluminum housing with glass
Z=Indicator indicator color: Red and silver flags
Z=Indicator mounting : Standard orientation (180° from process connections)
التوصيل: UPS، FedEx و DHL
توصيل دولي متاح
شحن في نفس اليوم للمتوفر في الموقع
يمكن التفاوض على تفاصيل الشحن
سياسة الشحن المجمع: نقوم بدمج الشحنات لتقليل التكاليف للعملاء الذين يشترون عدة عناصر.
بعد إتمام العملاء لعمليات الشراء المتعددة، يجب عليهم طلب فاتورة.
سنقوم بتغليف ووزن الشراء بالكامل وتقديم فاتورة تشمل الشحن والتعبئة.
الضمان: جميع منتجاتنا مغطاة بضمان ريمان
سنقوم بتسجيل فيديو اختباري قبل الشحن
✓ ضمان 30 يومًا - قطع مجددة
الإرجاع: سياسة إرجاع بدون تعقيدات.
عروض أسعار سريعة: احصل على السعر والتوفر اليوم!
الدفع:
You have already visited today.Today's Visitors: 943
Yesterday's Visitors: 984
Total Visits: 564643
Most Visitors on 2026-05-18: 2949
Pages Visited in the Last 24 Hours:
- /product/Indicator-703041-181-140-25-000-dTRON-316-Jumo
- /product/Temperature-3144P-D6A2I1M5T1Q4U1QTXA-Rosemount
- /product/PH-ORP-Conductivity-DO-Analyzer-3-2726-10-GF
- /
- /
- /categories/Level
- /categories/DAQ
- /categories/Flowmeter
- /categories/Valves
- /categories/Temperature
- /categories/Gas-Detection
- /categories/Pressure
- /categories/PH-ORP-Conductivity-DO-Analyzer
- /product/Level-FEW54-Endress-Hauser
- /product/Level-FTS-20-Endress-Hauser
- /product/Indicator-HXDSBOXAI-485-JIT
- /manufacturer-popular/Turck
- /manufacturer-popular/Advantech
- /manufacturer-popular/CTC
- /manufacturer-popular/samson
- /manufacturer-popular/Rosemount
- /manufacturer-popular/IFM
- /product/PH-ORP-Conductivity-DO-Analyzer-3-9900-1P-GF
- /manufacturer-popular/ABB
- /product/Level-FMR51-Flang-Endress-Hauser
- /product/Pressure-700G05-FLUKE
- /manufacturer-popular/Pepperl-Fuchs
- /manufacturer-popular/JIT
- /manufacturer-popular/Moxa
- /manufacturer-popular/OMRON
- /manufacturer-popular/PHOENIX-CONTACTS
- /manufacturer-popular/B-K
- /manufacturer-popular/Emerson
- /manufacturer-popular/Fisher
- /manufacturer-popular/Vega
- /manufacturer-popular/WIKA
- /product/Level-DTI200-A14A1A-Endress-Hauser
- /manufacturer-popular/Endress-Hauser
- /manufacturer-popular/Schneider
- /manufacturer-popular/Bently-Nevada
- /product/Level-T32-1S-0IS-LVL-KSR-Kuebler
- /manufacturer-popular/Siemens
- /manufacturer-popular/National-instrument
- /manufacturer-popular/Yokogawa
- /manufacturer-popular/KSR-Kuebler
- /product/Pressure-EJA110A-EHS4B-22DB-Yokogawa
- /manufacturer-popular/Allen-Bradley
- /manufacturer-popular/KROHNE
- /product/Proximity-31000-16-10-00-159-00-02-Bently-Nevada
- /product/Level-FTS-20-Endress-Hauser
- /product/Level-RTG-3960-Emerson
- /product/Indicator-Head-indicator-pressure-JIT
- /product/Level-FMU90-R21CA232AA3A-Endress-Hauser
- /product/Proximity-IG5497-IFM
- /product/Portable-ZX21-Resistor-Junction-JIT
- /product/Proximity-NG5010-IFM
- /product/Temperature-5081-P-HT-Rosemount
- /product/Accessory-0306RT22BA11-Rosemount
- /product/Valves-Y53-Other
- /product/Level-2051L2AB4GD21AAF1C1-Rosemount
- /product/Temperature-248RANA-Rosemount
- /product/Flowmeter-DK800-R-RA-KROHNE
- /product/Proximity-IN0108-IFM
- /product/DAQ-DAM-3058F-JIT
- /product/Level-FEL56-Endress-Hauser
- /product/Level-FEL58-Endress-Hauser
- /product/Level-FMR53-Endress-Hauser
- /product/Level-FEL85-Endress-Hauser
- /product/Level-FHB20-Endress-Hauser
- /product/Level-FMP40-7KK2AEJB2BJA-Endress-Hauser
- /product/Level-FMP40-ABB2AWJB213A-Endress-Hauser
- /product/Level-FTM20-AM43A-Endress-Hauser
- /product/Pressure-2051TG-Rosemount
- /product/Flowmeter-8600DF040SK1N2P1RM-Rosemount
- /product/Level-ftm51-aahcs4a13aa-Endress-Hauser
- /product/Pressure-1301F-Fisher
- /product/Lvdt-AC192-1D-CTC
- /product/DAQ-PD3060-PT100-JIT
- /product/Level-FDU96-RG1A-Endress-Hauser
- /product/Level-FDU92-RG6A-Endress-Hauser
- /product/Vibration-AC192-1A-CTC
- /product/Temperature-644HANAM5-Emerson
- /product/Pressure-PMC731-R11S1E21M1-Endress-Hauser
- /product/Indicator-C72-k301-PE-JIT
- /product/Level-FTL62-AAA2ACATT2CTEBE2T-Endress-Hauser
- /product/Flowmeter-CMFS100M329N3E6E2ZZ-Micro-Motion
- /product/Temperature-444RL2U1D2C6-Rosemount
- /product/Level-fmr51-Endress-Hauser
- /product/Temperature-TT4C-JIT
- /product/Temperature-TMT182-ACKBA-Endress-Hauser
- /product/Level-FTL51B-AAA2ABAAA2CCI1VCC-Endress-Hauser
- /product/Temperature-3044CA1B4M5-Rosemount
- /product/Level-FTM51-AGJ2M4D13AF-Other
- /product/Accessory-52028122-Endress-Hauser
- /product/Level-FMU43-APH2A2-Endress-Hauser
- /product/Pressure-PMD75-ABA7FJ1DAAA-Endress-Hauser
- /product/Pressure-PMD75-HBA7B21DAAA-Endress-Hauser
- /product/Pressure-PMD75-ABA7C21DAAA-Endress-Hauser
- /product/Level-FMP40-1AA2ADJB21CY-Endress-Hauser
- /product/DAQ-SCB-68-National-instrument
- /product/Level-VEGAMET-861-Vega
- /product/Pressure-BWX-WIKA
- /product/Accessory-52028092-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-Endress-Hauser
- /product/DAQ-NI-9237-National-instrument
- /product/Level-FMB50-AA21RA-Endress-Hauser
- /product/Pressure-PMD75-ABA7F21DAAA-Endress-Hauser
- /product/Level-FMU40-ARB2A2-Endress-Hauser
- /product/Level-FTL33-AA4U3ABWSJ-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-COS41-4F-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CLM223-CD0110-Endress-Hauser
- /product/Temperature-TR66-AEABC2X22KA0-Endress-Hauser
- /product/Flowmeter-AD25AAAAABAA1-Endress-Hauser
- /product/Pressure-2290PG1-Rosemount
- /product/Level-FMP54-BAACCAAED2YYY-EFMB-Endress-Hauser
- /product/Flowmeter-93WA1-AB2C10ACABAA-Endress-Hauser
- /product/Pressure-PMD75-ABC7B21BAAA-Endress-Hauser
- /product/DAQ-9203-National-instrument
- /product/Proximity-LR12-D150N1D-JIT
- /product/Level-FTL51-ATE2CB4E5A-Endress-Hauser
- /product/Flowmeter-UD0A1AA0AAAA-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-LEVEL-Endress-Hauser
- /product/Level-FMU40-ARB1A2-Endress-Hauser
- /product/Pressure-PMD75-ABA7H21DAAA-Endress-Hauser
- /product/Vibration-LP202-4R1-1E-CTC
- /product/Pressure-PMD75-ABC7D21BAAA-Endress-Hauser
- /product/Level-FMR245-7GCQKAA2-Endress-Hauser
- /product/Level-FMR50-AAAAAABMGGF-Endress-Hauser
- /product/Flowmeter-55S1H-UR0B2AC4BAAA-Endress-Hauser
- /product/Level-FTL51-GAF2BB8G6R-Endress-Hauser
- /product/Level-FTL31-AA4U3BAWSJ-Endress-Hauser
- /product/Temperature-3144PD1A1NAM5XA-Rosemount
- /product/Proximity-IPS-308-OP-18-JIT
- /product/Pressure-PMD75-ABA7C21BASA-Endress-Hauser
- /product/Level-FMR51-FDACCDBBA5ARJ-AAJALA75-Endress-Hauser
- /product/Level-FMP40-5PP2CRJB21AA-Endress-Hauser
- /product/Level-FMR52-8L68-0-Endress-Hauser
- /product/Indicator-HZN-450755P0224-ABB
- /product/Level-FMP51-AACCCDLBB3RDJ-EBZ1-Endress-Hauser
- /product/Pressure-PMC71-1BA2FBRDAAA-Endress-Hauser
- /product/Pressure-3051TG3A2B-Rosemount
- /product/Level-FMU40-1RB2A4-Endress-Hauser
- /product/Gas-BH-60-H2S-JIT
- /product/Pressure-PMD75-ACA7C212AAA-Endress-Hauser
- /product/Pressure-S-20-WIKA
- /product/Proximity-330130-Bently-Nevada
- /product/Flowmeter-5P2B80-4P14-101-Endress-Hauser
- /product/Level-FTM20-4G42A-Endress-Hauser
- /product/Flowmeter-53P40-ASGB4DA0AAAA-Endress-Hauser
- /product/Level-FTL50-GGF2AA7G5A-Endress-Hauser
- /product/Power-Electric-SH201-C20-ABB
- /product/Temperature-4253A01R4AA00-Other
- /product/PLC-HMI-FX2N-40M-JIT
- /product/Level-FMR532-1WC8JAC2GA-Endress-Hauser
- /product/Level-FDU93-TN1A-Endress-Hauser
- /product/Pressure-S-10-WIKA
- /product/Level-FMP51-AAACCALAA4RGJ-AA-Endress-Hauser
- /product/Level-FMP40-7KK3AFJB21GB-Endress-Hauser
- /product/Accessory-71319979-Endress-Hauser
- /product/Flowmeter-5P2B50-5PL3-125-Endress-Hauser
- /product/Flowmeter-53P4H-EL2B2AA0AAAA-Endress-Hauser
- /product/Pressure-1151DP5S22C2M7Q4-PRESSURE-Rosemount
- /product/Pressure-PMD75-5BA7D21BAAA-Endress-Hauser
- /product/Level-FTL81-BBSAAAA1ACJWDJ-Endress-Hauser
- /product/Proximity-330103-Bently-Nevada
- /product/Pressure-FMB70-ABA1HA2CFCAA-Endress-Hauser
- /product/DAQ-cDAQ-9188-National-instrument
- /product/Pressure-PMD75-ABA7F21BAAA-Endress-Hauser
- /product/Pressure-PMD75-ABA7L12FAQK-NVN8Z1-Endress-Hauser
- /product/Accessory-2-3-9300-108-Rosemount
- /product/Pressure-700G05-FLUKE
- /product/Accessory-XPD0037-AAA100-Endress-Hauser
- /product/Accessory-TID10-E1-Endress-Hauser
- /product/Temperature-TMT162-F2121KBKA-Endress-Hauser
- /product/Pressure-PMD75-AAA7L11BAAA-Endress-Hauser
- /product/Level-FTL51-RAF2CB4E5A-Endress-Hauser
- /product/Level-BGU-E-KSR-KUEBLER
- /product/PH-ORP-Conductivity-DO-Analyzer-CLM431-H3B2IA-Endress-Hauser
- /product/Vibration-VC-1100-C11-B-K
- /product/Level-FMP40-1KK2AMJK21AN-Endress-Hauser
- /product/Level-FTL62-BBA7ABANN2CNEAE2JEH-Endress-Hauser
- /product/Temperature-644-1050-0001-AF-Rosemount
- /product/Level-FMM20-B14B1AD1G1-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-NH-KpH-JIT
- /product/Flowmeter-53P80-ECHB1AA0ABAA-Endress-Hauser
- /product/Pressure-FMD76-ABA7H2KBAA-Endress-Hauser
- /product/Accessory-K9803HC-Yokogawa
- /product/Proximity-330104-Bently-Nevada
- /product/Level-FTM51-1YY2L8A32AY-Endress-Hauser
- /product/Power-Electric-MK3P-I-OMRON
- /product/Pressure-3051CD2A22A1AS2B4-Rosemount
- /product/Level-FMU44-AVB2A22A-Endress-Hauser
- /product/Level-FTL51-EAE2BB4F7A-Endress-Hauser
- /product/Flowmeter-5H3B15-AAIBAEAFAAFDAS0AA2-LPLT-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-400VP-11-Rosemount
- /product/Temperature-TPR100-BXX2CCAA0-Endress-Hauser
- /product/Flowmeter-40E15-AFTSAABAA5AA-Endress-Hauser
- /product/Pressure-2051CG5A02A1AH2B1M5DF-Rosemount
- /product/Valves-TZIDC-V18345-ABB
- /product/Level-FTL20-042C-Endress-Hauser
- /product/Vibration-TK-83-Bently-Nevada
- /product/Level-FTM51-AB39M4A12AA-Endress-Hauser
- /product/Pressure-PMP46-RA13MBA1YYD-Endress-Hauser
- /product/Pressure-PMD75-78X49-142-Endress-Hauser
- /product/Level-FTM51-AGG2L2A32AA-LEVEL-Endress-Hauser
- /product/Level-FMU95-J11CAB31A-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUS31-A2E-Endress-Hauser
- /product/Pressure-3051CD1A02A1AM5B7DFK8H2L4T104-Rosemount
- /product/Pressure-3051CD4AC2A1AH2M5B1C6-Rosemount
- /product/Pressure-PMD75-570D3-264-Endress-Hauser
- /product/Proximity-BI20-G47-AZ3X-Turck
- /product/Pressure-1151GP6S22R1M7B3DFQ4-Rosemount
- /product/Accessory-K9800TA-Yokogawa
- /product/Temperature-TMT142-O1111JCKA1-Endress-Hauser
- /product/Accessory-6FX8002-5CS01-1AF0-Siemens
- /product/Pressure-PMD75-ANA7B21BAAA-Endress-Hauser
- /product/Temperature-3144PD2A1E5B4M5Q4-Temperature-Rosemount
- /product/Level-FMP55-BCACCBCAAGKAEJDLAOEZ1-Endress-Hauser
- /product/Pressure-PMP46-RE13MBA1YYD-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUS31-W2A-Endress-Hauser
- /product/Flowmeter-8F3B1H-BDECACGFABSDAASCA1-Endress-Hauser
- /product/Proximity-IB0016-IBE2020-FB0A-IFM
- /product/Level-FTM50-AGK2K4A32AA-Endress-Hauser
- /product/Temperature-TMT182-H31BA-Endress-Hauser
- /product/Temperature-248HANAN0NSQ4-Rosemount
- /product/Flowmeter-FMR57-AAACADBDA6RGJ2-AAOP-Endress-Hauser
- /product/Temperature-644HAK5M5J6Q4XA-Rosemount
- /product/Pressure-PMD75-HBA7F81DCAA-Z1-Endress-Hauser
- /product/Pressure-PMC71-ABA1C2GP1AA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2G-Endress-Hauser
- /product/Level-FTL50-AGN2AA2G5A-Endress-Hauser
- /product/Pressure-PMC71-ACA2FBGABAA-Endress-Hauser
- /product/Valves-YVP110-Yokogawa
- /product/Flowmeter-50P1F-AR0A1BA0B4AW-Endress-Hauser
- /product/Pressure-3051CD4A02A1BS5E5M5-Rosemount
- /product/Level-FTL51-KAE2BB4G5A-Endress-Hauser
- /product/Level-FMR51-AAACCABDA5AHJ-Endress-Hauser
- /product/Other-Manifold-5-way-Rosemount
- /product/Level-FMB51-AA22IA1FGD80GGJB2U-ABHC-Endress-Hauser
- /product/Level-FTM51-AGK2M2A32AA-Endress-Hauser
- /product/Level-FTL50-GAF2AA8G5C-Endress-Hauser
- /product/Level-FTL50-DGQ2AA4G4A-Endress-Hauser
- /product/Flowmeter-80F1F-CABSBACAABAA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM253-PR1616-Endress-Hauser
- /product/Level-FTL50-AGM2AA5E5A-Endress-Hauser
- /product/Temperature-TMT82-BAA2AB1A1AAA1-LA-Endress-Hauser
- /product/Flowmeter-5H3B04-BSIBAAAFAAAD5S1BA1-Endress-Hauser
- /product/Level-FTM20-4G42A-FEM24-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CLS50-G1B2-Endress-Hauser
- /product/Flowmeter-55S1H-UHJB1A34ADAB-Endress-Hauser
- /product/Level-FTM51-AGGAL2A34AA-Endress-Hauser
- /product/Pressure-3051L4AA0FD21AAM5C6-Rosemount
- /product/Pressure-PMP71-ABC1WC1RDAEA-Endress-Hauser
- /product/Flowmeter-65I-20AA0AD1RABACA-Endress-Hauser
- /product/Accessory-K9803WK-Yokogawa
- /product/Pressure-FMB52-BA22IA1FGA15CHJB2U-Endress-Hauser
- /product/Pressure-SDP6B45-A-250-Other
- /product/DAQ-USB-6009-OEM-National-instrument
- /product/Level-FMR240-43V1AEJAC4A-Endress-Hauser
- /product/Temperature-TMT182-A1KBA-Endress-Hauser
- /product/Level-FTL51C-ABGKBKDG4AA-Endress-Hauser
- /product/Level-VEGADIS-61-DIS61-CXAMD-Vega
- /product/Pressure-3051L4AADFD21AAC6M5-Rosemount
- /product/Flowmeter-GFC-300-KROHNE
- /product/Level-VEGASWING-61-DUABVXURX-Vega
- /product/Pressure-PMD75-1BJ7HE1DABA-Z1-Endress-Hauser
- /product/Level-PS62-UXCNE2FKNXX-Vega
- /product/Pressure-PMP71-ABC1U21RHAAA-Endress-Hauser
- /product/Gas-Detection-SC311S-100-ASSY-Emerson
- /product/Level-FMR231-AEGGJAA2AA-Endress-Hauser
- /product/Flowmeter-8750WDMR1A1FTSE015SA1M4Q4-Rosemount
- /product/Level-FTL50-YGQ2AA4G7A-Endress-Hauser
- /product/Level-FMP41C-SDTCKB21A4A-Endress-Hauser
- /product/Level-FTL51-FGR2BB7Y9A-Endress-Hauser
- /product/Pressure-3051L3AA0FD21AAM5C6-Rosemount
- /product/Pressure-PMP71-ABC1S21RAAAA-Endress-Hauser
- /product/Flowmeter-90WA1-AA2A10ACA4AA-Endress-Hauser
- /product/Level-FMU44-ATB2A23A-Endress-Hauser
- /product/Level-FTM50-AGG2A4D32AA-Endress-Hauser
- /product/Temperature-TMT182-1AAAA-Endress-Hauser
- /product/DAQ-PXI-6509-National-instrument
- /product/Flowmeter-FMU30-AAHEAAGGF-Endress-Hauser
- /product/Flowmeter-50P1F-BF5BRAC2AAAW-Endress-Hauser
- /product/Flowmeter-CMF050M-314NQFZEZZZHTMC-Emerson
- /product/Accessory-K9400FA-Yokogawa
- /product/Temperature-644HAE1J6M5Q4XA-Rosemount
- /product/Level-FMU30-AAHEABGHF-Endress-Hauser
- /product/Pressure-FMB70-AAA1H12CGCAA-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G4AA-Endress-Hauser
- /product/Pressure-PMD75-AAA7D21CAAU-Endress-Hauser
- /product/Level-FTL50-AGR2AA4G6A-Endress-Hauser
- /product/Pressure-2051L3AADFD21AAM5C6-Rosemount
- /product/Temperature-TR66-CCEEC2XCMDA0-Endress-Hauser
- /product/Accessory-K9802NA-Yokogawa
- /product/Flowmeter-8800CW060SD1N1D1Q4-Rosemount
- /product/Level-FMM50-A1A2A1AB11B1-Endress-Hauser
- /product/Pressure-PMC71-ABA1C2B4AAA-Endress-Hauser
- /product/Lvdt-VS-0169-B-K
- /product/Temperature-TR88-BB3B1D2MC0F0-Endress-Hauser
- /product/Flowmeter-8732EMR2A5K1AXM4C1B6Q4V2RT05HR7-Emerson
- /product/Level-FMR240-15K1YY9AA2D-Endress-Hauser
- /product/Power-Electric-3311DS1L1B2F2G7G8K5-Rosemount
- /product/Flowmeter-5W4C80-AAALHA0AHD3K0A-Endress-Hauser
- /product/Pressure-3051CG3A22A1AC6-Rosemount
- /product/Pressure-7MF4033-1EA00-2AB1-Siemens
- /product/Temperature-TR66-CEFED1XCKKB0-Endress-Hauser
- /product/Flowmeter-OPTIFLUX-4040-KROHNE
- /product/Pressure-PMD75-AAJ78812AAU-Endress-Hauser
- /product/Level-FTM31-A9BY110020IN-Endress-Hauser
- /product/Pressure-3051CD2A02A1AM5E5T1S5Q4-Rosemount
- /product/Pressure-PMC45-RE11F1A1AL4-Endress-Hauser
- /product/Level-9930068CAB1M00813SE2AB14SF9C8B9C8FA0ZZ-Rosemount