REEMAN Industrial Plant Equipment

Pressure PMD55-BA21BA77DGLHA4A1A+PB Endress+Hauser

Pressure PMD55-BA21BA77DGLHA4A1A+PB Endress+Hauser
Pressure PMD55-BA21BA77DGLHA4A1A+PB Endress+Hauser
Pressure PMD55-BA21BA77DGLHA4A1A+PB Endress+Hauser

Pressure PMD55-BA21BA77DGLHA4A1A+PB Endress+Hauser


  • رقم القطعة: PMD55-BA21BA77DGLHA4A1A+PB
  • الفئة: Pressure
  • الشركة المصنعة: Endress+Hauser
  • بلد المنشأ: Germany Country Germany
  • تاريخ الإصدار: 2023-12-12 19:12:26
  • فترة الانتظار: 3 to 4 working weeks
  • الحالة: New
  • رابط ورقة البيانات:
  • SKU: 34213491
  • التوفر: 1 in stock

PMD55-BA21BA77DGLHA4A1A+PB
Differential pressure transmitter with metal sensor for measurement of pressure differences
Approval: BA = ATEX II1/2G Ex ia IIC T6 Ga/Gb
Output: 2 = 4-20mA HART
Display, Operation: 1 = LCD, push button on display/electronics
Housing: B = F30 Alu, glass window
Electrical Connection: A = Gland M20, IP66/67 NEMA4X/6P
Nominal Pressure PN: 7 = 160bar/16MPa/2400psi
Sensor Nominal Value: 7D = 100mbar/10kPa/1.5psi
Reference Accuracy: G = Standard
Calibration; Unit: L = Customised flow; see additional spec.
Process Connection: HA4 = NPT1/4-18 IEC61518 UNF7/16-20, C22.8, V1 Installation impulse line vertical Alignment 90deg
Membrane Material: A = 316L
Fill Fluid: 1 = Silicone oil
Seal: A = FKM Viton
Accessory Enclosed: PB = Mounting bracket, wall/pipe, 316L, heavy duty design
التوصيل: UPS، FedEx و DHL
توصيل دولي متاح
شحن في نفس اليوم للمتوفر في الموقع
يمكن التفاوض على تفاصيل الشحن
سياسة الشحن المجمع: نقوم بدمج الشحنات لتقليل التكاليف للعملاء الذين يشترون عدة عناصر.
بعد إتمام العملاء لعمليات الشراء المتعددة، يجب عليهم طلب فاتورة.
سنقوم بتغليف ووزن الشراء بالكامل وتقديم فاتورة تشمل الشحن والتعبئة.
الضمان: جميع منتجاتنا مغطاة بضمان ريمان
سنقوم بتسجيل فيديو اختباري قبل الشحن
✓ ضمان 30 يومًا - قطع مجددة
الإرجاع: سياسة إرجاع بدون تعقيدات.
عروض أسعار سريعة: احصل على السعر والتوفر اليوم!
الدفع:
You have already visited today.Today's Visitors: 659
Yesterday's Visitors: 807
Total Visits: 220563
Most Visitors on 2025-07-14: 815
Pages Visited in the Last 24 Hours:
- /product/Indicator-ZJ-LCD-M-JIT
- /product/Indicator-LED5-4858T-JIT
- /product/Indicator-JSZS-V8-JIT
- /product/Vibration-330105-02-12-05-02-05-Bently-Nevada
- /product/Proximity-177313-02-02-Bently-Nevada
- /product/Vibration-330105-02-12-10-02-05-Bently-Nevada
- /product/Vibration-330103-00-03-10-02-05-Other
- /product/Indicator-Head-indicator-pressure-JIT
- /product/Pressure-1402252-01-001-ASHCROFT
- /product/Pressure-PMC51-AA21JA1FGBGVJB-Endress-Hauser
- /product/Indicator-KCMA-XJ4W-A-RS-JIT
- /product/Pressure-G2-0-3000psi-ASHCROFT
- /product/Pressure-G1-0-100psig-ASHCROFT
- /product/Vibration-124534-01-Bently-Nevada
- /product/Indicator-C72-k301-PE-JIT
- /product/Pressure-G1-0-30psig-ASHCROFT
- /product/Vibration-330180-50-05-Bently-Nevada
- /product/Pressure-G1-ASHCROFT
- /product/Indicator-HY304N-JIT
- /manufacturer/Rosemount
- /manufacturer/Advantech
- /manufacturer/Fisher
- /product/DAQ-Motion-Control-PCI-7390-National-instrument
- /product/DAQ-ADAM-3014-Converter-Advantech
- /product/Level-FTL50-FBE2AA6G5C-Endress-Hauser
- /product/Level-FMR51-AAACCABDA5CHJ-Endress-Hauser
- /product/DAQ-151840F-01L-USB-201-Other
- /product/DAQ-DAM-3058F-JIT
- /product/DAQ-cDAQ-9188-assemble-with-NI-9237-and-NI-9203-National-instrument
- /product/DAQ-ADAM-4017-Advantech
- /product/DAQ-RTU-Power-JIT
- /product/DAQ-SCB-100-National-instrument
- /product/DAQ-ADAM-4068-Advantech
- /product/DAQ-LFH-CONNECTOR-TO-TWO-MALE-D-SUB-CONNECTORS-3FT-National-instrument
- /product/DAQ-EDA9018A-JIT
- /product/DAQ-IPEH-004027-PEAK
- /product/DAQ-KL-W6000-JIT
- /product/DAQ-PCI-1220U-Advantech
- /product/DAQ-CP-114EL-V1-3-1-Moxa
- /product/DAQ-PCI-1240U-Advantech
- /product/DAQ-cDAQ-9188-National-instrument
- /product/DAQ-NI-USB-9162-National-instrument
- /product/DAQ-PCI-4472-National-instrument
- /product/DAQ-PXIe-8861-National-instrument
- /product/DAQ-NPort-5650-8-DT-Moxa
- /product/DAQ-NI-9162-NI-9237-National-instrument
- /product/DAQ-USB-4432-National-instrument
- /product/DAQ-PD3060-PT100-JIT
- /product/DAQ-HK16D485ADAM-JIT
- /product/DAQ-USB-6009-OEM-National-instrument
- /product/DAQ-C2000-MD44-JIT
- /product/DAQ-SCSI-68-pin-Other
- /product/DAQ-PCI-6602-NI-National-instrument
- /product/DAQ-PCIE-6323-National-instrument
- /product/DAQ-DI148-U-Other
- /product/DAQ-USB-6211-National-instrument
- /product/DAQ-PCI-6602-National-instrument
- /product/DAQ-PCI-4474-National-instrument
- /product/DAQ-PCI-6601-National-instrument-National-instrument
- /product/DAQ-NPort-5650I-8-DT-Moxa
- /product/DAQ-MIL-STD-1558-2-National-instrument
- /product/DAQ-PCI-6601-NI-National-instrument
- /product/DAQ-USB-6210-National-instrument
- /manufacturer/Bently-Nevada
- /product/DAQ-PCI-5122-National-instrument
- /product/DAQ-NI-9237-National-instrument
- /product/DAQ-40P-40M-Foxboro
- /product/DAQ-MIL-STD-1553-National-instrument
- /product/DAQ-USB-6009-National-instrument
- /product/DAQ-PCI-6221-National-instrument
- /product/DAQ-9203-National-instrument
- /product/DAQ-PCI-6221-37PIN-National-instrument
- /product/DAQ-PCI-6225-National-instrument
- /product/DAQ-S-7050-JIT
- /product/DAQ-PXI-6509-National-instrument
- /product/DAQ-PCI-1711UL-Advantech
- /product/DAQ-LFH-CONNECTOR-TO-FOUR-MIL-STD-1553-National-instrument
- /product/DAQ-NI-9237-with-DSUB-National-instrument
- /product/DAQ-PXI-6225-National-instrument
- /manufacturer/Emerson
- /manufacturer/HBM
- /manufacturer/ASHCROFT
- /manufacturer/National-instrument
- /product/PLC-HMI-1794-IB32-Allen-Bradley
- /product/PLC-HMI-1794-OB32P-1794-IRT8-Allen-Bradley
- /product/PLC-HMI-1756-L71-Allen-Bradley
- /manufacturer/Allen-Bradley
- /product/PLC-HMI-1771-DB-Allen-Bradley
- /product/PLC-HMI-2097-V32PRO-LM-Allen-Bradley
- /product/PLC-HMI-1746-NO8I-Allen-Bradley
- /product/PLC-HMI-1747-L553-Allen-Bradley
- /product/Pressure-3051TG2A2B21AB4K5M5-Rosemount
- /product/Flowmeter-63FS15-ABW40B20-Endress-Hauser
- /product/Flowmeter-5P1B2H-GRDBAAAAD3K0A-Endress-Hauser
- /product/Level-FMU43-APH2A2-Endress-Hauser
- /product/Flowmeter-53P40-ASGB4DA0AAAA-Endress-Hauser
- /product/Level-FTL33-AA4M3AB3CJ-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2G-Endress-Hauser
- /product/Flowmeter-50W1F-UC0A1AC29BAA-Endress-Hauser
- /product/Level-FEI57C-Endress-Hauser
- /product/Level-FMU43-APG2A2-Prosonic-Endress-Hauser
- /product/Level-FTL81-BBSAAAA1ACJWDJ-Endress-Hauser
- /product/Flowmeter-91WA1-AA2A00ACA4AA-Endress-Hauser
- /product/Level-FTL33-AA4W3ABWSJ-Endress-Hauser
- /product/Flowmeter-AXF150C-PNAL1L-CA11-2NB-Yokogawa
- /product/Indicator-RIA14-BA4C-Endress-Hauser
- /product/Flowmeter-9W4BA1-28R4-0-Endress-Hauser
- /product/Flowmeter-72W15-SK0AA4CAB4AW-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM442-CAM1A2F060A-ABZ1-Endress-Hauser
- /product/Level-VEGAPULS-69-PS69-IXBXDCHXAMXXX-Vega
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM223-PS0110-Endress-Hauser
- /product/Flowmeter-AXG025-GA000BA1AL210B-1DA12-GRL-CH-Yokogawa
- /product/Level-FMU43-APG2A2-LEVEL-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA21-Endress-Hauser
- /product/Flowmeter-80F80-AD2SAAAAAAA8-Endress-Hauser
- /product/Flowmeter-53P1F-ECHB1AA0ABAA-Endress-Hauser
- /product/Flowmeter-TFM1100-P-Aktek-Other
- /product/Level-FMP51-AAACCDLBA4RGJ-AANCPB-Endress-Hauser
- /product/Level-FTL33-AA4M3ABWSJ-Endress-Hauser
- /product/Flowmeter-80F1F-CABSBACAABAA-Endress-Hauser
- /product/Level-FTL50-DGQ2AA4G4A-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM442-8AM2A2F211B-AA-Endress-Hauser
- /product/Flowmeter-5H3B04-BSIBAAAFAAAD5S1BA1-Endress-Hauser
- /product/Level-FMP45-1BKCRJB21A2B-Endress-Hauser
- /product/Pressure-PMP75-1B11SC2AFADE-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPK9-HAZ3A-Endress-Hauser
- /product/Flowmeter-5H3B04-AAIBAEAFAABI3S5BA2-LA-Endress-Hauser
- /product/Level-FMU30-AAHEABGHF-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-Endress-Hauser
- /product/Level-FTL51-DGQ2BB7G4C-Endress-Hauser
- /product/Flowmeter-50P1F-BF5BRAC2AAAW-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-e-h-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-COS41-4F-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM253-MS1010-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11E-BA7BAA2-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2C-Endress-Hauser
- /product/Level-FTI51-N6M1AFK44D1A-Endress-Hauser
- /product/Flowmeter-5H3B15-AAIBAEAFAAFDAS0AA2-LPLT-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G5AA-Endress-Hauser
- /product/Level-FTL50-AGM2AA5E5A-Endress-Hauser
- /product/Temperature-TMT82-NAA2AB3A1A1A2-with-display-TID10-B1-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-Endress-Hauser
- /product/Level-FMP41C-SDTCKB21A4A-Endress-Hauser
- /product/Level-FTL51C-ABGKBKDG4AA-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-LEVEL-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G4AA-Endress-Hauser
- /product/Flowmeter-50P15-EL0A1AA0ABAA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM42-IAA000EBZ00-Endress-Hauser
- /product/DAQ-GS3-U3-23S6C-FLIR
- /product/Level-FMR51-I3LCCDBCA5YYY-AAF3JAJBKEKIKRZ1-Endress-Hauser
- /product/Level-FMR245-7GCQKAA2-Endress-Hauser
- /product/Level-FMP40-1AA2ADJB21CY-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CYK10-A031-Endress-Hauser
- /product/Level-FMU40-1RB2A4-Endress-Hauser
- /product/Flowmeter-33AT25-AB1AA11A21A-Endress-Hauser
- /product/Level-FTL20H-0TDJ2E-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-3-9900-1P-GF
- /product/Level-FTC262-AA34D1-Endress-Hauser
- /product/Level-DB51-AE10BA11GG20-Endress-Hauser
- /product/Level-FMB53-BE21JA1FGA15B3A-ABPO-Endress-Hauser
- /product/Level-FMI51-D1FGGJC3A1A-Endress-Hauser
- /product/Flowmeter-TFM-1100P-Aktek
- /product/Flowmeter-53P80-ECHB1AA0ABAA-Endress-Hauser
- /product/Flowmeter-PF2W704-F03-67-SMC
- /product/Flowmeter-IFC300-F-DIV2-KROHNE
- /product/PH-ORP-Conductivity-DO-Analyzer-EP0010Z1-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-OUSAF11-AA110C1A50E-Endress-Hauser
- /product/Level-FMR532-1WC8JAC2GA-Endress-Hauser
- /product/Level-VEGAVIB-61-VB61-XXAGGRKMX-Other
- /product/Level-FTM51-AGG2L2A32AA-LEVEL-Endress-Hauser
- /product/Level-FMP57-MFV4-0-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CYK10-A051-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CCM253-EP0105-Endress-Hauser
- /product/Level-FMP40-7KK2AEJB2BJA-Endress-Hauser
- /product/Level-FMI51-A1EGEJB3A1A-Endress-Hauser
- /product/Flowmeter-65I-20AA0AD1AAAAB6-Endress-Hauser
- /product/Level-FMP40-1AA4CRJB11AA-Endress-Hauser
- /product/Level-FTL50-AGR2AA4G6A-Endress-Hauser
- /product/Level-FMU90-R21CA232AA3A-Endress-Hauser
- /product/Flowmeter-30DT65-AB1AA11A11B-Endress-Hauser