REEMAN Industrial Plant Equipment

Pressure PMP51-AA12QA2MGJJJJJTBJA3JA Endress+Hauser

Pressure PMP51-AA12QA2MGJJJJJTBJA3JA Endress+Hauser
Pressure PMP51-AA12QA2MGJJJJJTBJA3JA Endress+Hauser

Pressure PMP51-AA12QA2MGJJJJJTBJA3JA Endress+Hauser


  • رقم القطعة: PMP51-AA12QA2MGJJJJJTBJA3JA
  • الفئة: Pressure
  • الشركة المصنعة: Endress+Hauser
  • بلد المنشأ: Germany Country Germany
  • تاريخ الإصدار: 2023-11-05 17:11:30
  • فترة الانتظار: 3 to 4 working weeks
  • الحالة: like New
  • رابط ورقة البيانات:
  • SKU: 37524713
  • التوفر: 1 in stock

Cerabar M PMP55 - Process pressure measurement
Approval AA: Non-hazardous area
Output 1: 4-20mA
Display, Operation 2: W/o LCD, push button on electronics
Housing Q: F15 stainless steel hygiene
Electrical Connection A: Gland M20, IP66/68 NEMA4X/6P
Sensor Range 2M: 4bar/400kPa/60psi abs,
40mH2O/133ftH2O/1600inH2O abs overload:
28bar/2.8MPa/420psi
Reference Accuracy G: Standard
Calibration; Unit J: Customised pressure; see additional
spec.
Low range value J: 0,000 bar
Upper range value J: 3,000 bar
2nd value display J: none
Damping [s] J: 2
Process Connection TBJ: Clamp ISO2852 DN18-22, 316L DIN32676
DN15-20, EHEDG, 3A, ASME-BPE
Membrane Material A: 316L
Fill Fluid 3: Synthetic oil, FDA
Test, Certificate JA: 3.1 Material certificate, wetted
metallic parts, EN10204-3.1 inspection
certificate
التوصيل: UPS، FedEx و DHL
توصيل دولي متاح
شحن في نفس اليوم للمتوفر في الموقع
يمكن التفاوض على تفاصيل الشحن
سياسة الشحن المجمع: نقوم بدمج الشحنات لتقليل التكاليف للعملاء الذين يشترون عدة عناصر.
بعد إتمام العملاء لعمليات الشراء المتعددة، يجب عليهم طلب فاتورة.
سنقوم بتغليف ووزن الشراء بالكامل وتقديم فاتورة تشمل الشحن والتعبئة.
الضمان: جميع منتجاتنا مغطاة بضمان ريمان
سنقوم بتسجيل فيديو اختباري قبل الشحن
✓ ضمان 30 يومًا - قطع مجددة
الإرجاع: سياسة إرجاع بدون تعقيدات.
عروض أسعار سريعة: احصل على السعر والتوفر اليوم!
الدفع:
You have already visited today.Today's Visitors: 659
Yesterday's Visitors: 807
Total Visits: 220563
Most Visitors on 2025-07-14: 815
Pages Visited in the Last 24 Hours:
- /product/Indicator-ZJ-LCD-M-JIT
- /product/Indicator-LED5-4858T-JIT
- /product/Indicator-JSZS-V8-JIT
- /product/Vibration-330105-02-12-05-02-05-Bently-Nevada
- /product/Proximity-177313-02-02-Bently-Nevada
- /product/Vibration-330105-02-12-10-02-05-Bently-Nevada
- /product/Vibration-330103-00-03-10-02-05-Other
- /product/Indicator-Head-indicator-pressure-JIT
- /product/Pressure-1402252-01-001-ASHCROFT
- /product/Pressure-PMC51-AA21JA1FGBGVJB-Endress-Hauser
- /product/Indicator-KCMA-XJ4W-A-RS-JIT
- /product/Pressure-G2-0-3000psi-ASHCROFT
- /product/Pressure-G1-0-100psig-ASHCROFT
- /product/Vibration-124534-01-Bently-Nevada
- /product/Indicator-C72-k301-PE-JIT
- /product/Pressure-G1-0-30psig-ASHCROFT
- /product/Vibration-330180-50-05-Bently-Nevada
- /product/Pressure-G1-ASHCROFT
- /product/Indicator-HY304N-JIT
- /manufacturer/Rosemount
- /manufacturer/Advantech
- /manufacturer/Fisher
- /product/DAQ-Motion-Control-PCI-7390-National-instrument
- /product/DAQ-ADAM-3014-Converter-Advantech
- /product/Level-FTL50-FBE2AA6G5C-Endress-Hauser
- /product/Level-FMR51-AAACCABDA5CHJ-Endress-Hauser
- /product/DAQ-151840F-01L-USB-201-Other
- /product/DAQ-DAM-3058F-JIT
- /product/DAQ-cDAQ-9188-assemble-with-NI-9237-and-NI-9203-National-instrument
- /product/DAQ-ADAM-4017-Advantech
- /product/DAQ-RTU-Power-JIT
- /product/DAQ-SCB-100-National-instrument
- /product/DAQ-ADAM-4068-Advantech
- /product/DAQ-LFH-CONNECTOR-TO-TWO-MALE-D-SUB-CONNECTORS-3FT-National-instrument
- /product/DAQ-EDA9018A-JIT
- /product/DAQ-IPEH-004027-PEAK
- /product/DAQ-KL-W6000-JIT
- /product/DAQ-PCI-1220U-Advantech
- /product/DAQ-CP-114EL-V1-3-1-Moxa
- /product/DAQ-PCI-1240U-Advantech
- /product/DAQ-cDAQ-9188-National-instrument
- /product/DAQ-NI-USB-9162-National-instrument
- /product/DAQ-PCI-4472-National-instrument
- /product/DAQ-PXIe-8861-National-instrument
- /product/DAQ-NPort-5650-8-DT-Moxa
- /product/DAQ-NI-9162-NI-9237-National-instrument
- /product/DAQ-USB-4432-National-instrument
- /product/DAQ-PD3060-PT100-JIT
- /product/DAQ-HK16D485ADAM-JIT
- /product/DAQ-USB-6009-OEM-National-instrument
- /product/DAQ-C2000-MD44-JIT
- /product/DAQ-SCSI-68-pin-Other
- /product/DAQ-PCI-6602-NI-National-instrument
- /product/DAQ-PCIE-6323-National-instrument
- /product/DAQ-DI148-U-Other
- /product/DAQ-USB-6211-National-instrument
- /product/DAQ-PCI-6602-National-instrument
- /product/DAQ-PCI-4474-National-instrument
- /product/DAQ-PCI-6601-National-instrument-National-instrument
- /product/DAQ-NPort-5650I-8-DT-Moxa
- /product/DAQ-MIL-STD-1558-2-National-instrument
- /product/DAQ-PCI-6601-NI-National-instrument
- /product/DAQ-USB-6210-National-instrument
- /manufacturer/Bently-Nevada
- /product/DAQ-PCI-5122-National-instrument
- /product/DAQ-NI-9237-National-instrument
- /product/DAQ-40P-40M-Foxboro
- /product/DAQ-MIL-STD-1553-National-instrument
- /product/DAQ-USB-6009-National-instrument
- /product/DAQ-PCI-6221-National-instrument
- /product/DAQ-9203-National-instrument
- /product/DAQ-PCI-6221-37PIN-National-instrument
- /product/DAQ-PCI-6225-National-instrument
- /product/DAQ-S-7050-JIT
- /product/DAQ-PXI-6509-National-instrument
- /product/DAQ-PCI-1711UL-Advantech
- /product/DAQ-LFH-CONNECTOR-TO-FOUR-MIL-STD-1553-National-instrument
- /product/DAQ-NI-9237-with-DSUB-National-instrument
- /product/DAQ-PXI-6225-National-instrument
- /manufacturer/Emerson
- /manufacturer/HBM
- /manufacturer/ASHCROFT
- /manufacturer/National-instrument
- /product/PLC-HMI-1794-IB32-Allen-Bradley
- /product/PLC-HMI-1794-OB32P-1794-IRT8-Allen-Bradley
- /product/PLC-HMI-1756-L71-Allen-Bradley
- /manufacturer/Allen-Bradley
- /product/PLC-HMI-1771-DB-Allen-Bradley
- /product/PLC-HMI-2097-V32PRO-LM-Allen-Bradley
- /product/PLC-HMI-1746-NO8I-Allen-Bradley
- /product/PLC-HMI-1747-L553-Allen-Bradley
- /product/Pressure-3051TG2A2B21AB4K5M5-Rosemount
- /product/Flowmeter-63FS15-ABW40B20-Endress-Hauser
- /product/Flowmeter-5P1B2H-GRDBAAAAD3K0A-Endress-Hauser
- /product/Level-FMU43-APH2A2-Endress-Hauser
- /product/Flowmeter-53P40-ASGB4DA0AAAA-Endress-Hauser
- /product/Level-FTL33-AA4M3AB3CJ-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2G-Endress-Hauser
- /product/Flowmeter-50W1F-UC0A1AC29BAA-Endress-Hauser
- /product/Level-FEI57C-Endress-Hauser
- /product/Level-FMU43-APG2A2-Prosonic-Endress-Hauser
- /product/Level-FTL81-BBSAAAA1ACJWDJ-Endress-Hauser
- /product/Flowmeter-91WA1-AA2A00ACA4AA-Endress-Hauser
- /product/Level-FTL33-AA4W3ABWSJ-Endress-Hauser
- /product/Flowmeter-AXF150C-PNAL1L-CA11-2NB-Yokogawa
- /product/Indicator-RIA14-BA4C-Endress-Hauser
- /product/Flowmeter-9W4BA1-28R4-0-Endress-Hauser
- /product/Flowmeter-72W15-SK0AA4CAB4AW-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM442-CAM1A2F060A-ABZ1-Endress-Hauser
- /product/Level-VEGAPULS-69-PS69-IXBXDCHXAMXXX-Vega
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM223-PS0110-Endress-Hauser
- /product/Flowmeter-AXG025-GA000BA1AL210B-1DA12-GRL-CH-Yokogawa
- /product/Level-FMU43-APG2A2-LEVEL-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA21-Endress-Hauser
- /product/Flowmeter-80F80-AD2SAAAAAAA8-Endress-Hauser
- /product/Flowmeter-53P1F-ECHB1AA0ABAA-Endress-Hauser
- /product/Flowmeter-TFM1100-P-Aktek-Other
- /product/Level-FMP51-AAACCDLBA4RGJ-AANCPB-Endress-Hauser
- /product/Level-FTL33-AA4M3ABWSJ-Endress-Hauser
- /product/Flowmeter-80F1F-CABSBACAABAA-Endress-Hauser
- /product/Level-FTL50-DGQ2AA4G4A-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM442-8AM2A2F211B-AA-Endress-Hauser
- /product/Flowmeter-5H3B04-BSIBAAAFAAAD5S1BA1-Endress-Hauser
- /product/Level-FMP45-1BKCRJB21A2B-Endress-Hauser
- /product/Pressure-PMP75-1B11SC2AFADE-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPK9-HAZ3A-Endress-Hauser
- /product/Flowmeter-5H3B04-AAIBAEAFAABI3S5BA2-LA-Endress-Hauser
- /product/Level-FMU30-AAHEABGHF-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-Endress-Hauser
- /product/Level-FTL51-DGQ2BB7G4C-Endress-Hauser
- /product/Flowmeter-50P1F-BF5BRAC2AAAW-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS41-2BC2ESS-e-h-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-COS41-4F-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPM253-MS1010-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11E-BA7BAA2-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CPS11D-7BA2C-Endress-Hauser
- /product/Level-FTI51-N6M1AFK44D1A-Endress-Hauser
- /product/Flowmeter-5H3B15-AAIBAEAFAAFDAS0AA2-LPLT-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G5AA-Endress-Hauser
- /product/Level-FTL50-AGM2AA5E5A-Endress-Hauser
- /product/Temperature-TMT82-NAA2AB3A1A1A2-with-display-TID10-B1-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-Endress-Hauser
- /product/Level-FMP41C-SDTCKB21A4A-Endress-Hauser
- /product/Level-FTL51C-ABGKBKDG4AA-Endress-Hauser
- /product/Level-FTL51C-ACGSFSDG4KA-LEVEL-Endress-Hauser
- /product/Level-FTL51C-DBGKBK2G4AA-Endress-Hauser
- /product/Flowmeter-50P15-EL0A1AA0ABAA-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CM42-IAA000EBZ00-Endress-Hauser
- /product/DAQ-GS3-U3-23S6C-FLIR
- /product/Level-FMR51-I3LCCDBCA5YYY-AAF3JAJBKEKIKRZ1-Endress-Hauser
- /product/Level-FMR245-7GCQKAA2-Endress-Hauser
- /product/Level-FMP40-1AA2ADJB21CY-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CYK10-A031-Endress-Hauser
- /product/Level-FMU40-1RB2A4-Endress-Hauser
- /product/Flowmeter-33AT25-AB1AA11A21A-Endress-Hauser
- /product/Level-FTL20H-0TDJ2E-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-3-9900-1P-GF
- /product/Level-FTC262-AA34D1-Endress-Hauser
- /product/Level-DB51-AE10BA11GG20-Endress-Hauser
- /product/Level-FMB53-BE21JA1FGA15B3A-ABPO-Endress-Hauser
- /product/Level-FMI51-D1FGGJC3A1A-Endress-Hauser
- /product/Flowmeter-TFM-1100P-Aktek
- /product/Flowmeter-53P80-ECHB1AA0ABAA-Endress-Hauser
- /product/Flowmeter-PF2W704-F03-67-SMC
- /product/Flowmeter-IFC300-F-DIV2-KROHNE
- /product/PH-ORP-Conductivity-DO-Analyzer-EP0010Z1-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-OUSAF11-AA110C1A50E-Endress-Hauser
- /product/Level-FMR532-1WC8JAC2GA-Endress-Hauser
- /product/Level-VEGAVIB-61-VB61-XXAGGRKMX-Other
- /product/Level-FTM51-AGG2L2A32AA-LEVEL-Endress-Hauser
- /product/Level-FMP57-MFV4-0-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CYK10-A051-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CCM253-EP0105-Endress-Hauser
- /product/Level-FMP40-7KK2AEJB2BJA-Endress-Hauser
- /product/Level-FMI51-A1EGEJB3A1A-Endress-Hauser
- /product/Flowmeter-65I-20AA0AD1AAAAB6-Endress-Hauser
- /product/Level-FMP40-1AA4CRJB11AA-Endress-Hauser
- /product/Level-FTL50-AGR2AA4G6A-Endress-Hauser
- /product/Level-FMU90-R21CA232AA3A-Endress-Hauser
- /product/Flowmeter-30DT65-AB1AA11A11B-Endress-Hauser
- /product/Pressure-PMD55-BA21BA77DGLHA4A1A-PB-Endress-Hauser
- /product/Flowmeter-50W2F-HLGE1AA0AABW-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUE22-A1A-Endress-Hauser
- /product/Level-FTL50H-STE2AC6E4A-Endress-Hauser
- /product/Flowmeter-50W4H-UD0A1AA0AAAA-Endress-Hauser
- /product/Flowmeter-65F25-AE2AG1AAABCA-Endress-Hauser
- /product/Level-FTM20-4G42A-FEM24-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CUS31-A2E-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-3-2726-10-GF
- /product/Level-FTC260-AB4B2-Endress-Hauser
- /product/Flowmeter-OPTIFLUX2050C-KROHNE
- /product/Flowmeter-93WA1-AB2C10ACABAA-Endress-Hauser
- /product/Level-FMR51-BBELCABBA5AFJ-EM-Endress-Hauser
- /product/Level-FMU42-APB2A22A-Endress-Hauser
- /product/PH-ORP-Conductivity-DO-Analyzer-CLD133-MV5PK1-Endress-Hauser
- /product/Level-FMU42-APB2A22A-Ultrasonic-Endress-Hauser
- /product/Level-FTI77-N1SFRRGJ43D1A-Endress-Hauser
- /product/Flowmeter-AXF015G-PNAL1L-AA1-2NB-Yokogawa
- /product/Pressure-PMP71-1BA2P162AAAA-Endress-Hauser
- /product/Level-FMI52-K3BGGJB3A1A-Endress-Hauser
- /product/Level-FMP53-3235-0-Endress-Hauser
- /product/Pressure-PMP75-1BA1PB1AS1DU-Endress-Hauser
- /product/Pressure-PMP51-AA12QA2MGJJJJJTBJA3JA-Endress-Hauser
REEMAN Industrial Plant Equipment REEMAN Industrial Plant Equipment L.L.C +971-509129535 +971-509129535 info@reemanindustrial.com