Type : Electromagnetic flowmeter
Model : OPTIFLUX 2100C
Order code of flow sensor : VN1446501303113001000000000
Order code of signal converter : VN3104A0660010100000
Type OPTIFLUX 2100 C Primary head OPTIFLUX 2000
Compact model
Meter size : DN 40 / 1 1/2"
Connection : DN 40 PN 40
Mounting length : 200 mm / 7.87" - ISO 13 359 excl.gaskets & rings
Flange material : steel 1.0460 (C 22.8)
Housing : Sheet metal
Lining : Polypropylene
Fluid temperature : max. 90 °C / 194 °F. depending on pressure.
Electrodes : Hastelloy C4 fixed electrodes with 2 electrodes construction
Insulation class of coi : H
Protection class : IP 66/67 (NEMA 4X/6) acc. EN 60 529
Installation instruction : multi-language
Tagplate : 67 x 25 mm / 2.64 x 0.98"
Material : 304 / 1.4301
Tagno. : see calibration data
Calibration : GKL
PED group 1 - liquids
SEP
APPLICATION DATA
medium : cooling water
temperature : 35 °C
pressure : 10 bar
measured range : 0 ... 22 m³/h
tag no. : HC11 FT 212111
tag no. : HC11 FT 212121
KROHNE flow converter
Type : IFC 100 C
Compact model (0°)
Empty pipe detection, conductivity
Incl. software : PACTWARE
Accuracy : +/- 0,3% v MV see TDS
Power supply : 100-230 V AC, 50/60 Hz (85-250 V)
Cable connection : 2 x M20 x 1,5
Operation manual : Without
Programming : English
Process diagnostic : Standard
Gas content, function of electrodes,
temperature.
Converter housing : Standard, aluminum
Communication : Basic I/O
1. Current output : HART, active / passive
2. Pulse / status outp. : passive
3. Status output : passive
APPLICATION DATA
puls output 1 : 10 Imp/m3
current output 1 : 4 ... 20 mA
display : m3/h
Material Certificate
Type of instrument : Aquaflux / OPTIFLUX 2000
Process connection : Flange
For : Flange/tube/electrode/electrodebush
Meter size : Standard according to manual DN10-3000 - 3/8"-120"
Range of test : Without
Certificate : WB 2.1
Language : Standard (GE/EN/FR)
Supervision : Without
*** 3 x instrument to be sent to KIT separately
Calibration
Type of instrument : Standard according manual
Meter size : DN25-150 - DN1"-6"
Range of test : Standard
Specification : Standard
Acceptance criteria : Standard
Certificate : Standard
Language : English
Supervision :Without
التوصيل: |
UPS، FedEx و DHL
توصيل دولي متاح
شحن في نفس اليوم للمتوفر في الموقع
يمكن التفاوض على تفاصيل الشحن
|
سياسة الشحن المجمع: |
نقوم بدمج الشحنات لتقليل التكاليف للعملاء الذين يشترون عدة عناصر.
بعد إتمام العملاء لعمليات الشراء المتعددة، يجب عليهم طلب فاتورة.
سنقوم بتغليف ووزن الشراء بالكامل وتقديم فاتورة تشمل الشحن والتعبئة.
|
الضمان: |
جميع منتجاتنا مغطاة بضمان ريمان
سنقوم بتسجيل فيديو اختباري قبل الشحن
✓ ضمان 30 يومًا - قطع مجددة
|
الإرجاع: |
سياسة إرجاع بدون تعقيدات.
|
عروض أسعار سريعة: |
احصل على السعر والتوفر اليوم!
|
الدفع: |
|